a. Where there is only one exit staircase or scissors-staircase serving the dwelling units, the minimum waist of exit staircase and the thickness of the intermediate landing slab shall be 150mm. The staircase shall be constructed of reinforced concrete.

b. If the exit staircase or scissors-staircase are designed as the S/C SS, the waist of the staircase shall be minimum 200mm.