2.4 STATION WITH PLATFORMS LOCATED SIDE BY SIDE SEPARATED BY TRAINWAY

2.4.1 Under each scenario, as defined under Cl.2.2.2, the exit capacity for the incident platform shall cater for one train peak load for the largest available train serving that platform (the train load shall not be split between the two platforms).

2.4.2 Refer to Diagram 2.4.2 – 1 & 2 for the occupant load calculations under two scenarios for an underground station with two platforms located side by side.