TABLE 1.2A : CODES & STANDARDS |
---|
Name
| Description
| Remarks
|
---|
SINGAPORE STANDARDS
|
---|
SS CP 5
| CoP for Wiring of Electrical Equipment of Buildings
| |
SS CP 10
| CoP for Installation and Servicing of Electrical Fire Alarm
System
| |
SS CP 52 | CoP for Automatic Fire Sprinkler System | |
SS 99 | Specifications for Welded Low Carbon Steel Cylinders for Storage and Transportation of Low-Pressure Liquefiable Gases
| |
SS 232 Pt 1 to 6 | Portable Fire Extinguishers
| Replaced
by SS EN 3 - 7 to 10
|
SS 233 | Specifications for Flexible Rubber Tubing, Rubber Hose and Rubber Hose Assemblies for Use in LPG Vapour Phase Installations
| |
SS 254 | Electrical Apparatus for Explosive Gas Atmospheres
| Replaced by IEC 60079
|
SS 263 Pt 2 | Luminaires - Particular Requirements for Luminaires for Emergency Lighting | Replaced by SS IEC 60598-2-22
|
SS 281 | Specifications for Pressure Regulators for LPG
| |
SS 286 | Caution Labelling for Hazardous Substances
| Replaced by SS 586
|
SS 294 | Specifications for Valves for Use with Domestic and Industrial LPG Cylinders
| |
SS 299 | Fire Resistant Cables
| |
SS 332 | Specification for Fire Door
| |
SS 333 | Specification for Fire Dampers
| |
SS 489 | Specification for Fire Shutters
| |
SS 508 | Graphical Symbols - Safety Colours & Safety Signs
| Formerly SS 217 & SS
|
Pt 1
| Design Principles for Safety Signs & Safety Markings
| |
Pt 2
| Design Principles for Product Safety Labels
| |
SS 532 | CoP for the Storage of Flammable Liquids | Formerly CP 40
|
SS 535 | CoP for Installation, Operation, Maintenance, Performance astructional Requirements of Mains Failure Standby Generating Systems
| Formerly CP 31
|
SS 546 | CoP for Emergency Voice Communication Systems in Buildings
| Formerly CP 25
|
SS 550 | CoP for Installation, Operation and Maintenance of El Passenger and Goods Lifts
| Formerly CP 2
|
SS 551 | CoP for Earthing | Formerly CP 16 |
SS 563 | CoP for the Design, Installation & Maintenance of Em Lighting and Power Supply Systems in Building
| Formerly CP 19
|
Pt. 1 | Emergency lighting | |
Pt. 2 | Installation Requirements and Maintenance Procedures | |
SS 572 | CoP for the Use of Timber in Buildings | Formerly CP 1
|
SS 575 | CoP for Fire Hydrant, Rising Mains and
Hose Reel Sypan> | Formerly CP 29 |
SS 578 | CoP for Use and Maintenance of Portable
Fire Exhers | Formerly CP 55 |
SS 586 | Specification for Hazard Communication for Hazardous Chemicals and Dangerous Goods
| Replaces SS 286
|
SS 608 | CoP for Gas Installation
| Formerly CP 51
|
SS EN
3-7 | Portable Fire Extinguishers - Part 7 : Characteristics, performance requirements and test methods | Replaces SS 232 Pt. 1 to 6
|
SS EN
3-8 | Portable Fire Extinguishers - Part 8 : Additional requirements to SS EN 3-7 for the construction, resistance to pressure and mechanical tests for extinguishers with a maximum allowable pressure equal to or lower than 30 bar | Replaces SS 232 Pt. 1 to 6
|
SS EN
3-9 | Portable Fire Extinguishers - Part 9 : Additional requirements to SS EN 3-7 for pressure resistance if CO extinguishers |
SS EN
3-10 | Portable Fire Extinguishers - Part 10 : Provisions for evaluating the conformity of a portable fire extinguisher to SS EN 3-7 |
AMERICAN STANDARDS
|
---|
ASTM D635 | Standard Test Method for Rate of Burning and/or Extent &Time of Burning of Plastics in a Horizontal Position
| |
ASTM
E108 | Standard Test Methods for Fire Tests of Roof Coverings
| |
ASTM E119
| Standard Test Methods for Fire Tests of Building Construction
& Materials
| |
NFPA 16
| Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems
| Formerly NFPA 16A |
NFPA 30
| Flammable
& Combustible Liquids Code | |
NFPA 33
| Standard for Spray Application Using Flammable or Combustible Materials
| |
NFPA 45
| Standard on Fire Protection for Laboratories Using Chemicals
| |
NFPA 54
| National Fuel Gas Code
| |
NFPA 55
| Compressed Gases and Cryogenic Fluids Code
| |
NFPA 58
| Liquefied Petroleum Gas Code
| |
NFPA 251
| Standard Methods of Tests of Fire Resistance of Building Construction & Materials | |
NFPA 262
| Standard Methods of Tests for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces
| |
NFPA 400
| Hazardous Materials Code
| |
NFPA 430
| Code for the Storage of Liquids & Solid Oxidizers
| Replaced by NFPA 400 |
NFPA 432
| Code for the Storage of Organic Peroxide Formulations
|
NFPA 495
| Explosive Materials Code
| |
NFPA 502
| Standard for Road Tunnels, Bridges and other Limited Access Highways
| |
NFPA 750
| Standard on Water Mist Fire Protection Systems
| |
UL 132 | Standard for Safety
Relief Valves for Anhydrous
Ammonia and LP-Gas | |
UL 144 | Standard for LP-Gas Regulators
| |
UL 300
| Standard for Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment
| |
AUSTRALIAN STANDARDS
|
---|
AS 1530
| Methods for Fire Tests on Building Materials, Components & Structures | |
Pt 4 | Fire-resistance Test of Elements of Construction | |
AS 2208
| Safety Glazing Materials in Buildings
| |
AS 2714
| The Storage & Handling of Organic Peroxides
| |
AS 2941
| Fixed Fire Protection Installations - Pumpset Systems | |
AS 4391
| Smoke Management Systems - Hot Smoke Test | |
AS 4326
| The Storage & Handling of Oxidizng Agents
| |
AS 4587
| Water Mist Fire Protection Systems - System Design, Installation and Commissioning | |
BRITISH STANDARDS
|
---|
BR 186
| Design Principles for Smoke Ventilation in Enclosed Shopping
Centres
| Published by Fire
Research Station, Building Research Establishment, Borehamwood, Herts WD62BL
|
BR 258
| Design Approaches for Smoke Control in Atrium Buildings
|
BR 368
| Design Methodologies for Smoke and Heat Exhaust Ventilation
| Published by Con- struction Research Communications Ltd by permission of Building Re- search Establish- ment Ltd
|
BS 476
| Fire Tests on Building Materials and Structures
| |
Pt 4 | Non-Combustibility Test for Materials
| |
Pt 5
| Method of Test for Ignitability
| |
Pt 6
| Method of Test for Fire Propagation for Products
| |
Pt 7
| Method of Test to Determine the Classification of the Surface Spread of Flame of Products
| |
Pt 11
| Method for Assessing the Heat Emission from Building Materials
| |
Pt 20
| Method for Determination of the Fire Resistance of Elements of Construction (General Principles)
| |
Pt 21
| Methods for Determination of the Fire Resistance of Load- Bearing Elements of Construction
| |
Pt 22
| Method for Determination of the Fire Resistance of Non-Load- Bearing Elements of Construction
| |
Pt 23
| Methods for Determination of the Contribution of Components to the Fire Resistance of a Structure
| |
Pt 24
| Method for Determination of the Fire Resistance of Ventilation Ducts
| |
BS 1230 Pt 1
| Specification for Plasterboard Excluding Materials Submitted to Secondary Operations
| Replaced by BS EN 520
|
BS 2594
| Specification for Carbon Steel Welded Horizontal Cylindrical Storage Tanks
| Withdrawn
|
BS 3016
| Specifications for Pressure Regulators for LPG
| Withdrawn
|
BS 4514
| Specification for Unplasticized PVC Soil and Ventilating Pipes of 82.4mm Minimum Mean Outside Diameter, and Fittings and Accessories of 82.4mm and of Other Sizes
| |
BS 5041
| Fire Hydrant Systems Equipment
| |
Pt 1
| Specification for Landing Valves for Wet Risers
| |
Pt 3
| Specification for Inlet Breechings for Dry Riser Inlets
| |
BS 5234
| Partitions (including matching linings)
| |
Pt 2
| Specification for Performance Requirements for Strength and Robustness including Methods of Test
| |
BS 5345
| Selection, Installation and Maintenance of Electrical Apparatus for Use in Potentially Explosive Atmosphere (Other than Mining Applications or Explosive Processing and Manufacturing)
| Replaced by BS EN 60079-14
|
Pt 1
| General Recommendations
|
Pt 3
| Installation and Maintenance Requirements for Electrical Apparatus with Type of Protection ‘d’. Flameproof Enclosure
|
BS 5499
| Fire Safety Signs, Notices and Graphic Symbols
| |
Pt 2
| Specification for Self-Luminous Fire Safety Signs
| Withdrawn
|
BS 5588
| Fire Precautions in the Design, Construction and Use of Buildings | |
Pt 5
| CoP for Firefighting Stairways and Lifts
| Withdrawn
|
BS 5852
| Methods of Test for Assessment of the Ignitability of Upholstered Seating by Smouldering and Flaming Ignition Source
| |
BS 6206
| Specification for Impact Performance Requirements for Flat Safety Glass and Safety Plastics for Use in Buildings
| |
BS 6391
| Specification for Non-Percolating Layflat Delivery Hoses and Hose Assemblies for Fire Fighting Purposes
| |
BS 7346
| Components for Smoke and Heat Control Systems
| |
Pt 2
| Specification for Powered Smoke and Heat Exhaust Ventilators
| Withdrawn
|
Pt 3
| Specification for Smoke Curtains
| Withdrawn
|
BS 7346
| Components for Smoke and Heat Control Systems
| |
Pt 7
| CoP on Functional Recommendations and Calculation Methods for Smoke and Heat Control Systems for Covered Car Parks
| |
BS 8202
| Coatings for Fire Protection of Building Elements
| |
Pt 2
| CoP for the Use of Intumescent Coating Systems to Metallic Substrates for Providing Fire Resistance
| |
BS EN 54
| Fire Detection and Alarm Systems
| |
Pt 2
| Control and Indicating Equipment
| |
Pt 4
| Power Supply Equipment
| |
BS EN 520
| Gypsum Plasterboards. Definitions, Requirements and Test Methods | Replaces BS 1230 Pt 1
|
BS EN 12101-1
| Smoke & Heat Control Systems – Specification for Smoke Barriers
| Replaces BS 7346 Pt 3 |
BS EN 12101-3 | Smoke & Heat Control Systems – Specification for Powered Smoke & Heat Control Ventilators (Fans)
| Replaces BS 7346 Pt 2 |
BS EN 13501-1
| Fire Test to Building Materials - Classification
| |
BS EN 50054
| Electrical Apparatus for the Detection and Measurement of Combustible Gases. - General Requirements and Test Methods | |
BS EN 50057
| Electrical Apparatus for the Detection and Measurement of Combustible Gases. - Performance Requirements for Group II Apparatus Indicating up to 100% Lower Explosive Limit | |
BS EN 50272-2
| Safety Requirements for Secondary Batteries and Battery Installations. Stationary Batteries | Withdrawn |
BS EN 50272-3
| Safety Requirements for Secondary Batteries and Battery Installations. - Traction Batteries | Withdrawn |
BS EN 60079-14
| Explosive Atmosphere. Electrical Installations Design, Selection and Erection
| Replaces BS 5345 Pt. 1 & 3 |
BS EN IEC 62485-2
| Safety Requirements for Secondary Batteries and Battery Installations. - Stationary Batteries | Replaces BS EN 50272-2 |
BS EN IEC 62485-3
| Safety Requirements for Secondary Batteries and Battery Installations. - Traction Batteries | Replaces BS EN 50272-3 |
EUROPEAN STANDARDS
|
---|
EN 81 - 58
| Safety Rules for the Construction and Installation of Lifts. Examination and Tests. Part 58 - Landing Doors Fire Resistance Test | |
EN 671 - 1 | Fixed Firefighting Systems. Hose Systems. Hose Reels with Semi-Rigid Hose | |
EN 13823
| Reaction to Fire Tests for Building Products - Building Products excluding Floorings exposed to the Thermal Attack by a Single Burning Item | |
EN ISO 1182
| Reaction to Fire Tests for Products - Non-Combustibility Test | |
EN ISO 1716
| Reaction to Fire Tests for Building Products - Determination of the Gross Heat of Combustion (Calorific Value) | |
EN ISO 11925 -2
| Reaction to Fire Tests - Ignitability of Products subjected to Direct Impingement of Flame - Part 2 : Single Flame Source Test | |
IEC STANDARDS
|
---|
IEC 60079
| Explosive Atmospheres
| |
ISO STANDARDS
|
---|
ISO 834 | Fire resistance Tests - Elements of Building Construction | |
ISO 1896
| Thermal Insulating Asbestos Boards
| |
ISO 5149
| Refrigerating Systems and Heat Pumps - Safety and Environment Requirements | |